Products
Instruments
Advanced sweeping technology ensures precise PLT measurements.
SMART-FLOW patented liquid circuit for efficient operation.
High-definition 10.4-inch touchscreen (1366×768) with glove support.
Measurement technologies: Semiconductor laser scattering, flow cytometry, 3D scatter plots, and impedance analysis.
Comprehensive data visualization with 2D/3D scatter plots, WBC/BASO, RBC/PLT histograms.
Built-in printer and RFID card reader for seamless workflow.
Stores over 100,000 records, including histograms, scatter plots, and patient information.
3-Part Hematology Analyzer with 24 parameters.
3 histogram (WBC, RBC, PLT) and 3-level QC of L-J QC, X-B QC.
Smart counting mode, compact and lighter design, built-in card reader and highlighted indicator light.
Powerful data management - Flag information for better diagnostics.
Real-time monitoring - Reagent status, Unit status, Test count in different modes.
Smart maintenance - Hardware self-checking, multiple maintenance functions, smart prompt and one touch to remove error.
Memory up to 500000 sample results.
10.4 inch touch screen with built-in and support external printer.
4 USB ports for mouse, keyboard, external printer connectivity and 1 network port for communication.
3-Part Hematology Analyzer with 21 parameters and 3 histograms for WBC, RBC, and PLT (Platelet).
Accurate low-value PLT measurement using advanced cell pulse baseline tracking and restore technology.
Throughput of 60 samples per hour with a double chamber (WBC & RBC).
10.4-inch LCD touchscreen with a built-in printer and card reader.
One-key obstacle removal technology for quick fault elimination and efficient use.
Storage capacity for 500,000 sample results, including histograms and patient data.
Four USB ports with bi-directional LIS connection, supporting USB keyboard, mouse, USB disk, and USB printer.
3-Part Hematology Analyzer with 21 parameters and 3 histograms for WBC, RBC, and PLT (Platelet).
Accurate measurement for low-value PLT using advanced cell pulse baseline tracking and restore technology.
Detection speed optimized for efficiency, processing around 40 samples per hour with a double chamber (WBC & RBC).
10.4-inch LCD touchscreen with a built-in printer and card reader.
Equipped with one-key obstacle removal technology for quick fault elimination and efficient use.
Storage capacity for 500,000 sample results, including histograms and patient data.
Four USB ports with bi-directional LIS connection, supporting USB keyboard, mouse, USB disk, and USB printer.
Supports up to 10 methods of end point, fixed time, kinetics, multi-standards for all methods supports upto 10 standards and absorbance
Inventory management for monitoring of reagent stock and alerts on low stock.
All - in - one optical system, high reliability and anti-interference
6 filters (340 nm-630 nm) + 2 free positions.
Real time curve and QC graph print out
Dynamic temperature control of peltier elements, 25°C 30°C 37°C.
Up to 1000+ test profiles can be programmed
Memory for 500000+ sample results with editable patient information and curves for each test
Unlimited test results storage via cloud with wi-fi
4 USB ports, 1 ethernet port and HDMI port for external monitor
7 inch true color large display with touch screen
Endpoint method, two-point method, kinetic method.
The lamp can be turned ON and OFF through the program, which can effectively prolong the lifespan of the lamp.
Wavelength range 340nm - 630nm (340nm, 405nm, 492nm, 510nm, 546nm, 578nm, 630nm).
The quality control data and quality control charts can be printed.
Built-in thermal printer, which can print results and reaction curves in combination.
The well-designed circuit and heat dissipation structure improve the durability and anti-interference ability of the machine.
Absorbance range 0.000 - 3.000 ABS.
Light source of 12V/20W halogen lamp.
Storage of 100+ chemistry assays and 3700+ test results.
End point, fixed time, multi-point kinetics, multi-standards upto 8 standards and coagulation.
All - in - one optical system, high reliability and anti-interference
Separate Coagulation adapter and cuvettes for coagulation tests
7 filters (340 nm - 630 nm) + 2 free positions, ±2CML precision
Real time curve and Auto drawing of QC figures
Dynamic temperature control of peltier elements, 25°C 30°C, 37°C.
Up to 300 test profiles can be programmed
Memory for 200000 sample results with editable patient information
4 USB ports, 1 ethernet port and 1 USB Slave port
Built-in printer with support external printer
7 inch true color large display with touch screen
End point, fixed time, multi-point kinetics, multi-standards upto 8 standards and coagulation.
All - in - one optical system, high reliability and anti-interference
Separate Coagulation adapter and cuvettes for coagulation tests
7 filters (340 nm - 630 nm) + 2 free positions, ±2CML precision
Real time curve and Auto drawing of QC figures
Dynamic temperature control of peltier elements, 25°C 30°C, 37°C.
Up to 300 test profiles can be programmed
Memory for 200000 sample results with editable patient information
4 USB ports, 1 ethernet port and 1 USB Slave port
Built-in printer with support external printer
7 inch true color large display with touch screen
Test speed - Constant 150 tests/hour (Mono Reagent or Double Reagent).
The test principle is colorimetric method, turbidimetry, with methods including 1-point end, 2-point end, fixed-time, and kinetics.
Calibration type: Linear & Non-linear.
Reagent tray consists of 80 reagent positions (40 for R1 & 40 for R2), with a non-stop cooling system using a peltier pad inside (24 hours at 2°C - 15°C).
44 reaction cuvettes made of new amorphous optical plastics, ensuring perfect transmittance.
Reaction volume: 150μl - 330μl with a reaction time of 10 minutes.
Sample unit consists of 40 sample tray positions, with sample volume ranging from 2μl - 30μl (step by 0.1μl).
Sample probe features liquid surface detection, timely tracking for liquid volume, and collision avoidance.
Excellent mixer design with Teflon coating—prevents water dropping (reducing carryover) and provides excellent mixing effects with a standard mixing procedure.
High-precision ceramic syringe with a permanent ceramic piston, ensuring accurate dispensing as low as 0.1μl.
*Advanced operating system with automatic sample dilution (decrease, increase, normal).
Linear & non-linear calibration with multi-point calibration up to 8 points.
Automatic reaction results checking and warning.
Calibration results are automatically checked, with warning alarms and logs.
User-frendly instrument for professional users.
Wincol is microprocessor based electronically controlled digital colorimeter with 9 filters (410 nm - 640 nm)
Wincol is compact and simple to use with 1 ml solution.
Display in Percentage Transmission (%T), Absorbance (O.D) and 2 Concentration scales (C1 & C2) for final reporting values of samples/analytes.
Suitable for endpoint chemistries and absorbance measurement.
Inbuilt memory remains last K factor for concentration even after power off.
Long life LED light source
Unique facility of 410 nm Glycosylated Hemoglobin estimation.
User-frendly instrument for professional users.
Wincol is microprocessor based electronically controlled digital colorimeter with 9 filters (410 nm - 640 nm)
Wincol is compact and simple to use with 1 ml solution.
Display in Percentage Transmission (%T), Absorbance (O.D) and 2 Concentration scales (C1 & C2) for final reporting values of samples/analytes.
Suitable for endpoint chemistries and absorbance measurement.
Inbuilt memory remains last K factor for concentration even after power off.
Long life LED light source
Unique facility of 410 nm Glycosylated Hemoglobin estimation.
User-friendly instrument for professional users.
Wincol+ is a specially designed power supply and display card along with a 6.2V 700 mAH Ni-Card battery pack.
Wincol+ is a microprocessor based electronically controlled digital colorimeter with 9 filters (410 nm - 640 nm)
Wincol+ is compact and simple to use with 1 ml solution.
Display in Percentage Transmission (%T), Absorbance (O.D) and 2 Concentration scales (C1 & C2) for final reporting values of samples/analytes.
Suitable for endpoint chemistries and absorbance measurement.
Inbuilt memory remains the last K factor for concentration even after power off.
Long life LED light source
Unique facility of 410 nm Glycosylated Hemoglobin estimation.